好看的午夜成人网站_中文字幕久精品在线观看_久久国产加勒比精品无码_国产精品无码AV无码_97久久天天综合色

產品分類
您現在的位置:首頁 > 技術文章 > Schneider驅動器LTMR100CFM數據
Schneider驅動器LTMR100CFM數據
  • 更新日期:2023-09-15      瀏覽次數:670
    • Schneider 驅動器LTMR100CFM

      TeSys T是一種電機管理系統,當與短路保護和接觸器一起使用時,它提供完整的電機監控、控制和保護。它管理最關鍵的流程,同時減少停機時間,提高生產力,并預測流程中會發生什么,因為它可以在大范圍內準確監測電流、電壓和功率。該電機管理系統也是一個靈活的系統,支持六種通信協議,即Modbus™, CANopen,DeviceNet™, Profibus™, 以太網/IP和Modbus/TCP。TeSys T電機管理系統由幾個組件組成,包括LTMR控制器、擴展模塊、HMI和軟件以及幾個附件。LTMR控制器是管理基本功能的系統的主要組件。這包括對接地電流、電機溫度、電機三相電流的測量,控制器還包括用于故障管理的邏輯輸入和輸出

      Main
      RangeTeSys
      Product nameTeSys T
      device short nameLTMR
      Product or component typeMotor controller
      Device applicationEquipment monitoring and control
      Measurement current5…100 A
      [Us] rated supply voltage100...240 V AC 50/60 Hz
      Current consumption8...62.8 mA
      Supply voltage limits93.5…264 V AC
      Communication port protocolCANopen
      Bus typeCANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
      CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable

      Complementary
      [Ui] rated insulation voltage690 V conforming to EN/IEC 60947-1
      690 V conforming to CSA C22.2 No 14
      690 V conforming to UL 508
      [Uimp] rated impulse withstand voltage4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
      6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
      0.8 kV communication circuit conforming to EN/IEC 60947-4-1
      Short-circuit withstand100 kA conforming to EN/IEC 60947-4-1
      Associated fuse rating4 A gG for output
      0.5 A gG for control circuit
      Protection typeThermal protection
      Locked rotor
      Phase failure
      Earth-leakage protection
      Overload (long time)
      Power factor variation
      Phase unbalance
      Load fluctuation
      Thermal overload protection
      Reverse polarity protection
      Overload
      Network and machine diagnosis typeEvent recording
      Trip history information
      Starting current and time
      Running hours counter/operating time
      Motor control command recording
      Remaining operating time before overload tripping
      Fault recording
      Phase fault and earth fault trip counters
      Waiting time after overload tripping
      Trip context information
      Logic input number6
      Input current3.1 mA at 100 V
      7.5 mA at 240 V
      Current state 0 guaranteedLogic input: 0...40 V and <= 15 mA for 25 ms
      Current state 1 guaranteedLogic input: 79...264 V and >= 2 mA for 25 ms
      maximum output switching frequency2 Hz
      Load current5 A at 250 V AC for logic output
      5 A at 30 V DC for logic output
      Permissible power480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
      30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
      maximum operating rate1800 cyc/h
      Contacts type and composition1 NO + 1 NC fault signal
      3 NO
      Metering typeEarth-fault current
      Phase current I1, I2, I3 RMS
      Imbalance current
      Temperature
      Average current Iavg
      Measurement accuracy5...15 % earth fault current internal measurement
      1 % voltage (100...830 V)
      3 % power factor
      5 % earth fault current external measurement
      +/- 30 min/year internal clock
      0,02 temperature
      5 % active and reactive power
      0,02 current
      Overvoltage categoryIII
      Connection pitch5.08 mm